Thermal insulation materials are standardized under ASTM C518 and the International Energy Conservation Code (IECC) by their thermal resistance (R-value per inch of thickness, hr·ft²·°F/Btu / RSI in m²·K/W), ranging from fiberglass batts (R-3.1/in) to polyisocyanurate and closed-cell spray foam (R-6.5 to R-7.0/in).

View full Thermal Insulation R-Values spec sheet →

Sound Transmission Class (STC) is an integer rating standardized under ASTM E90 and ASTM E413 that quantifies airborne sound attenuation across interior wall, floor, and ceiling assemblies, ranging from STC 30 (normal conversation heard easily) to STC 50+ (IBC building code privacy standard for multi-family dwellings).

View full Sound Transmission Class (STC) Ratings spec sheet →

Specification Comparison Table

14 Parameters
Parameter / Spec
Governing Standards
ASTM C518 / ASTM C177 / IECC Chapter 4 / ASHRAE 90.1 ASTM E90 / ASTM E413 / ISO 717-1 (Weighted Sound Reduction Index Rw) / IBC Section 1206
R-Value Definition
R = Thickness (inches) ÷ Thermal Conductivity (k-factor) in (hr·ft²·°F)/Btu
Fiberglass Batts (Standard)
R-3.1 to R-3.4 per inch | Density: 0.5–1.0 lb/cu ft | Permeable to air/vapor (Vapor Perm > 50)
Mineral Wool / Rockwool
R-3.8 to R-4.2 per inch | Non-combustible up to 1,177°C (2,150°F) | Excellent acoustic dampening
Expanded Polystyrene (EPS)
R-3.6 to R-4.0 per inch | White rigid beadboard | Vapor permeable
Extruded Polystyrene (XPS)
R-5.0 per inch | Blue/Pink closed-cell board | Moisture resistant, continuous foundation insulation
Polyisocyanurate (Polyiso)
R-6.0 to R-6.8 per inch | Foil-faced rigid foam | Superior continuous exterior sheathing
Closed-Cell Spray Foam (ccSPF)
R-6.5 to R-7.0 per inch | 2.0 lb density | Class II vapor barrier (< 0.8 Perm) + structural racking strength
STC 30 (Poor / Single Pane)
Normal conversation heard clearly through wall and easily understood
STC 35 (Basic Interior Partition)
Standard 2×4 wall with 1/2" drywall on each side (no insulation) | Loud speech heard and understood
STC 40 (Moderate Commercial)
Standard 2×4 wall + R-13 fiberglass batt insulation | Loud speech heard as muffled murmur
STC 45 (Good Privacy)
2×4 wall + batts + double layer 5/8" drywall on one side | Loud speech barely audible
STC 50 (IBC Building Code Minimum)
Multi-family party wall minimum under IBC 1206 (Staggered studs or Resilient Channel RC-1 + batts)
STC 55–60 (High-Performance Acoustic)
Double-stud wall (separated 1" air gap) + acoustic batts + Green Glue damping compound | Music bass highly attenuated