Thermal Insulation R-Values

Thermal Insulation & Acoustics · 8 specs

Direct Answer

Thermal insulation materials are standardized under ASTM C518 and the International Energy Conservation Code (IECC) by their thermal resistance (R-value per inch of thickness, hr·ft²·°F/Btu / RSI in m²·K/W), ranging from fiberglass batts (R-3.1/in) to polyisocyanurate and closed-cell spray foam (R-6.5 to R-7.0/in).

Source: ASTM C518 / ASTM C177 / IECC (International Energy Conservation Code) / ASHRAE 90.1 · Last reviewed Aug 28, 2026

Specs

Governing Standards ASTM C518 / ASTM C177 / IECC Chapter 4 / ASHRAE 90.1
R-Value Definition R = Thickness (inches) ÷ Thermal Conductivity (k-factor) in (hr·ft²·°F)/Btu
Fiberglass Batts (Standard) R-3.1 to R-3.4 per inch | Density: 0.5–1.0 lb/cu ft | Permeable to air/vapor (Vapor Perm > 50)
Mineral Wool / Rockwool R-3.8 to R-4.2 per inch | Non-combustible up to 1,177°C (2,150°F) | Excellent acoustic dampening
Expanded Polystyrene (EPS) R-3.6 to R-4.0 per inch | White rigid beadboard | Vapor permeable
Extruded Polystyrene (XPS) R-5.0 per inch | Blue/Pink closed-cell board | Moisture resistant, continuous foundation insulation
Polyisocyanurate (Polyiso) R-6.0 to R-6.8 per inch | Foil-faced rigid foam | Superior continuous exterior sheathing
Closed-Cell Spray Foam (ccSPF) R-6.5 to R-7.0 per inch | 2.0 lb density | Class II vapor barrier (< 0.8 Perm) + structural racking strength

Thermal Insulation Material R-Value Comparison Matrix

Insulation Material Type R-Value per Inch (ASTM C518) RSI Value per 25mm (Metric) Vapor Permeance (Perms) Water Absorption Fire / Ignition Behavior
Fiberglass Batts R-3.1 to R-3.4 / in 0.55 to 0.60 RSI > 50 Perms (Open) High (Loses R when wet) Non-combustible fibers
Mineral Wool (Rockwool) R-3.8 to R-4.2 / in 0.67 to 0.74 RSI > 30 Perms (Open) Hydrophobic (Repels water) Fireproof (2,150°F / 1,177°C)
Dense-Pack Cellulose R-3.6 to R-3.8 / in 0.63 to 0.67 RSI Vapor permeable Absorbs moisture Borate fire-retardant treated
EPS Rigid Foam (Beadboard) R-3.6 to R-4.0 / in 0.63 to 0.70 RSI 2.0 to 5.0 Perms Moderate (2% to 4%) Requires thermal barrier (drywall)
XPS Rigid Foam (Extruded) R-5.0 / in 0.88 RSI 0.8 to 1.5 Perms Very Low (< 0.7%) Requires thermal barrier
Polyiso (Foil-Faced) R-6.0 to R-6.8 / in 1.05 to 1.19 RSI < 0.05 Perms (Vapor Barrier) Low (< 1.0%) Excellent thermal sheathing
Open-Cell Spray Foam (0.5#) R-3.6 to R-3.8 / in 0.63 to 0.67 RSI 10 to 20 Perms High (Absorbs water) Excellent acoustic air-seal
Closed-Cell Spray Foam (2#) R-6.5 to R-7.0 / in 1.14 to 1.23 RSI < 0.8 Perms (Vapor Retarder) Zero (< 0.5%) Air barrier + Vapor barrier + Structure

Continuous Insulation (ci) vs Thermal Bridging in Studs

Wood studs (R ≈ 1.2 / in) and steel studs (R ≈ 0.001 / in) act as thermal bridges that bypass cavity insulation. A 2×6 wall with R-21 batt insulation has an effective overall assembly R-value of only R-15 due to 25% framing area framing loss. Adding 1.5 inches of exterior XPS continuous insulation (R-7.5 ci) breaks the thermal bridge completely.